Rotating a linear takeoff object that is set to "3-point curve" causes it to recalculate with slightly different results.Workaround: save changes to Condition name before drawing takeoff. Sometimes, after duplicating a Condition, if the name is still in edit mode and you draw takeoff, the cursor will not follow your movements.Be sure to review the System Requirements in Related Articles. Windows 8.1 users may view the MyOnCenter Tab contents here. As Windows 8.1 is no longer supported by On Center Software, this will not be fixed. The MyOnCenter Tab is not compatible with Windows 8.1 and will generate an error.As part of the new Auto Naming workflow, we have temporarily disabled the Auto Naming Results dialog box, this will be reintroduced as the Plan Details Editor in the next update to On-Screen Takeoff with improved functionality.Bug ON-3070 - Typical Groups cause performance degradation as more markers are placed in a project.See (Optional) Verify PTA Network Sensor Deployment.Improvements to the MyOnCenter Tab contents. If PTA is installed with Network Sensors, run the diagnostic tool to verify that the Network Sensors were properly reverted. Run the service appmgr restart command to restart PTA. If PTA is installed with Golden Ticket Detection configured, run the goldenTicketConfiguration.sh command to reactivate the PTAApp Vault user. If PTA is installed with Network Sensors, revert the Network Sensors using the snapshot that was saved in Step 1. This step is not needed when the reversion procedure occurs on the same day as the upgrade process. If the PTA upgrade process does not complete successfully, revert the PTA machine using the snapshot that was saved in Step 1.Īt the command line, in the /opt/tomcat/utility/ folder, run the vaultConfiguration.sh command to reconfigure the Vault connection. The PTA upgrade process is now complete and the following confirmation is displayed: When you open the log, address the error by searching for the version number and the task in which the error occurred. If any error messages appear, navigate to the log and resolve the issue. Verifying PTA version, expecting version 3.5… Īpplying PTA files and directories permissions… Verifying Linux OS version, expecting 'Centos 6 64-bit'. Taking a snapshot before performing an upgrade is highly recommended. Upgrade is supported from version 3.5 and above. Welcome to Privileged Threat Analytics version 3.95 upgrade tool.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |